Product Overview
The SINNOWA DS-161 is a fully automatic random-access biochemistry analyzer engineered for small-to-medium-sized clinical laboratories, hospitals, pet clinics, and research institutes requiring reliable, high-throughput automated chemistry testing. Manufactured by SINNOWA Medical Science & Technology Co., Ltd. under ISO 9001:2015 and ISO 13485:2016 certifications, the DS-161 delivers a throughput exceeding 160 tests per hour through a direct-reading optical system and advanced post-spectroscopy design. The analyzer accommodates 40 sample positions including standard, quality control, and emergency slots, with original test tubes and serum cup compatibility, and supports 42 reagent positions in standard configuration (24 R1 plus 18 R2) with a 2-8 degrees Celsius reagent refrigeration system. Its intelligent liquid-level detection, anti-collision protection, volume-tracking reagent probe, and automatic sample dilution/retest functions minimize manual intervention while maximizing result accuracy. The DS-161 supports endpoint, kinetic, fixed-time, single-wavelength, bichromatic, immunoturbidimetric, serum blank, single-standard, and multi-standard methodologies across a wavelength range of 330-850 nm. With AI-enabled software, multi-language support, automatic maintenance functions, an emergency sample priority channel, and storage for over 2 million patient records, the DS-161 combines compact dimensions with the performance typically expected from larger floor-standing chemistry analyzers.
Key Features & Advantages
- High throughput random-access processing: Exceeds 160 tests per hour with direct reading system, supporting continuous loading and priority emergency testing without interrupting routine workflows.
- Advanced optical system: Post-spectroscopy design with wavelength range 330-850 nm; 8 wavelengths as standard with 2 optional wavelengths; absorbance range 0-3.5 A and resolution 0.0001 A.
- Intelligent sample and reagent handling: Sensitive liquid surface detection, anti-collision protection, and volume-tracking function automatically monitor reagent volume down to 1 mL per bottle, reducing reagent waste and preventing sample probe crashes.
- Automatic dilution and retest: When sample results exceed the analytical range, the analyzer automatically dilutes and re-tests the sample, reducing manual dilution errors and improving laboratory efficiency.
- Ultra-low carry-over: Multiple innovative design technologies reduce carry-over to less than or equal to 0.01%, ensuring accurate results for high-concentration and low-concentration samples tested in sequence.
- Refrigerated reagent storage: 42 reagent positions with integrated 2-8 degrees Celsius refrigeration protect reagent stability and extend on-board reagent life.
- Intelligent error correction and quality control: Automatic error correction, intelligent QC functions, multi-rule Westgard-type control checking, and automatic correction when controls exceed range.
- Degassing and washing system: Innovative degassing device eliminates air bubbles in the liquid path; 5-channel automatic cuvette washing with separate high-concentration and low-concentration waste collection plus automatic cuvette drying.
- Emergency sample priority: Emergency samples can be inserted at any time for automatic priority processing, critical for ER and ICU laboratory workflows.
- AI-enabled software: Multiple artificial intelligence functions reduce operation difficulty and maintenance workload; supports multi-language interfaces and storage of over 5,000 test items and 2 million patient records.
- Pet diagnostic option: Can be optionally equipped with pet diagnostic software, making it suitable for veterinary clinics and animal research institutes.
Technical Specifications
- Model: SINNOWA DS-161 Fully Automatic Biochemistry Analyzer
- Manufacturer: SINNOWA Medical Science & Technology Co., Ltd. (Jurong, Zhenjiang, Jiangsu, China)
- Certifications: CE, ISO 9001:2015, ISO 13485:2016
- Assay type: Random access with direct reading system
- Methodology: End-point, kinetic, fixed time, single-wavelength, bichromatic, immunoturbidimetry, serum blank, single-standard, multi-standard method, etc.
- Throughput: Greater than 160 tests per hour
- Sample volume: 2-100 microliters, step size 0.1 microliter
- Reagent positions: 42 total (standard: 24 R1 + 18 R2)
- Reagent volume: 2-500 microliters, step size 0.1 microliter
- Sample positions: 40 positions including standard, quality control, and emergency; compatible with original test tubes and serum cups
- Refrigeration system: 2-8 degrees Celsius reagent compartment
- Mixing system: One independent stirrer
- Reagent/sample probe: Liquid surface detect, anti-collision, volume-tracking; detects remaining reagent volume down to 1 mL
- Reaction time: 10 minutes
- Cuvettes: Standard 60 high-quality micro plastic reaction cuvettes, transparent to ultraviolet and visible light
- Washing: 5-channel automatic cuvette washing; separate high-concentration and low-concentration waste collection; automatic cuvette drying
- Alarm system: Automatic alarm for malfunction, collision, reagent/sample insufficiency, full waste container, etc.
- Calibration: Linear and non-linear, multi-point calibration
- Sample dilution/retest: Automatic dilution and re-test when results are out of range
- Optical system: Advanced post-spectroscopy design
- Wavelength: 330-850 nm; 8 wavelengths standard, 2 additional optional
- Absorbance range: 0-3.5 A
- Resolution: 0.0001 A
- CV (coefficient of variation): Less than or equal to 1.0%
- Absorbance drift: Less than or equal to 0.002
- Temperature drift: No more than plus or minus 0.1 degrees Celsius
- Carry-over: Less than or equal to 0.01%
- System calibration: Blank background subtraction, automatic zero-adjustment; automatic cuvette blank recording and subtraction; automatic light source drift elimination
- Emergency test: Emergency samples can be inserted at any time for automatic priority testing
- Quality control: Multiple control types with various control rules; automatic check and correction when control results exceed range
- Software: AI-enabled functions; multi-language versions available; user-friendly operation interface
- Data storage: Can edit over 5,000 test items long-term; store over 2 million patient records long-term
- Printing: Multiple printing formats available
- Power supply: 220V 50Hz or 110V 60Hz
Test Menu
The DS-161 supports the full range of automated clinical chemistry, special proteins, and therapeutic drug monitoring assays, including:
- Liver function panel: ALT, AST, ALP, GGT, total bilirubin, direct bilirubin, total protein, albumin, globulin, A/G ratio, total bile acids
- Renal function panel: Urea, creatinine, uric acid, cystatin C, beta-2 microglobulin
- Cardiac markers: CK, CK-MB, LDH, alpha-HBDH
- Lipid profile: Total cholesterol, triglycerides, HDL-C, LDL-C, lipoprotein(a), apolipoprotein A1, apolipoprotein B
- Glucose and diabetes: Glucose, HbA1c, fructosamine, microalbumin
- Pancreatic enzymes: Amylase, lipase
- Electrolytes and minerals: Sodium, potassium, chloride, calcium, phosphorus, magnesium, iron, copper, zinc
- Inflammatory markers: CRP, high-sensitivity CRP, serum amyloid A
- Immune proteins: IgG, IgA, IgM, C3, C4, ASO, RF
- Coagulation-related: D-dimer, fibrinogen
- Therapeutic drug monitoring and toxicology: Drug and toxicity assays
Comparison & Competitive Advantages
Compared to the SINNOWA BS-3000M semi-automatic chemistry analyzer, the DS-161 delivers fully automated random-access operation with throughput exceeding 160 tests per hour versus the BS-3000M's manual step-by-step workflow. The DS-161 adds 40 sample positions, 42 refrigerated reagent positions, automatic sample dilution and retest, emergency priority processing, and AI-enabled software — capabilities essential for medium-throughput hospital laboratories. While the BS-3000M is ideal for small clinics and laboratories seeking a compact, budget-friendly semi-automatic analyzer, the DS-161 is designed for laboratories requiring higher automation, throughput, and sample capacity. Compared to other fully automatic analyzers in the 160-200 test/hour class, the DS-161 offers a compact footprint, lower performance cost, pet diagnostic software option, and ultra-low carry-over (less than or equal to 0.01%), making it a strong value proposition for small-to-medium hospitals, reference laboratories, and veterinary clinics. With over 20 years of IVD manufacturing experience and ISO 13485 certification, SINNOWA ensures consistent instrument quality and reagent compatibility across its analyzer portfolio.
Applications
- Small and medium hospital laboratories: Comprehensive routine chemistry, emergency chemistry, and outpatient testing with automatic priority for STAT samples.
- Clinical reference laboratories: Reliable throughput over 160 tests per hour supports moderate daily test volumes with minimal operator intervention.
- Pet clinics and veterinary hospitals: Optional pet diagnostic software enables chemistry testing for companion animals and research animals.
- Research institutes: Flexible methodology support and multi-point calibration accommodate research and development assays.
- Community health centers: Compact size and lower operating cost compared to large floor-standing analyzers make it accessible for smaller facilities.
- Backup analyzer in large laboratories: Serves as a dependable backup system during peak loads or maintenance of primary chemistry analyzers.
Frequently Asked Questions
Q: What is the SINNOWA DS-161 biochemistry analyzer?
A: The SINNOWA DS-161 is a fully automatic, random-access biochemistry analyzer with direct reading system. It performs over 160 tests per hour across endpoint, kinetic, fixed-time, bichromatic, and immunoturbidimetric methodologies, with automatic sample processing, reagent management, dilution, retest, and quality control.
Q: What is the throughput of the DS-161?
A: The DS-161 delivers throughput greater than 160 tests per hour, making it suitable for small-to-medium hospital laboratories and reference labs.
Q: How many samples and reagents can the DS-161 hold?
A: The analyzer has 40 sample positions (including standard, QC, and emergency positions) and 42 reagent positions in standard configuration (24 R1 + 18 R2), with 2-8 degrees Celsius reagent refrigeration.
Q: What sample volume does the DS-161 require?
A: The DS-161 requires only 2-100 microliters per test, with 0.1 microliter step size, enabling micro-volume sampling.
Q: What wavelengths does the DS-161 optical system support?
A: The optical system covers 330-850 nm with 8 standard wavelengths and 2 optional wavelengths, supporting a wide range of chemistry and immunoturbidimetric assays.
Q: Does the DS-161 support emergency sample testing?
A: Yes, emergency samples can be inserted at any time for automatic priority testing, which is essential for ER and ICU laboratory workflows.
Q: What happens if a sample result is out of range?
A: The DS-161 automatically dilutes and re-tests samples when results exceed the analytical range, eliminating manual dilution steps and reducing errors.
Q: Can the DS-161 be used for veterinary diagnostics?
A: Yes, the DS-161 can be optionally equipped with pet diagnostic software, making it suitable for pet clinics, veterinary hospitals, and animal research institutes.
Q: What is the carry-over rate of the DS-161?
A: The DS-161 achieves carry-over less than or equal to 0.01% through advanced washing and liquid path design, ensuring reliable sequential testing.
Q: Is the DS-161 LIS/HIS compatible?
A: Yes, the DS-161 supports data export and LIS/HIS connectivity, with storage for over 2 million patient records and over 5,000 programmable test items.
← Back to all products